The Intraligamental Syringe from Peak Surgicals is a reusable German Stainless Steel dental anesthetic delivery instrument designed for periodontal ligament injection, intraseptal anesthesia, endodontic supplemental anesthesia, restorative tooth-specific anesthesia, pediatric dental procedures, extraction support, and minor oral surgery. This syringe is priced at $66.00 and is listed in 0.5ml, 1ml, 2ml, 3ml, 5ml, 10ml, 20ml, 30ml, 50ml, and 60ml size variants for clinical ordering and anesthesia workflow selection. The visible design includes a pistol-grip frame, cartridge barrel, side viewing window, removable cartridge chamber, plunger rod, rear thumb plunger, trigger lever, needle hub connection, pressure-transfer mechanism, and polished stainless steel body for controlled local anesthetic expression. Dentists, oral surgeons, endodontists, pediatric dentists, periodontists, hospital dental departments, outpatient clinics, university dental programs, and procurement teams use this instrument during mandibular molar endodontics, failed block supplementation, crown preparation, deep caries excavation, pulpotomy, pulpectomy, tooth extraction, periodontal therapy, localized gingival manipulation, and single-tooth anesthesia where the periodontal ligament route is selected.
Pistol-Grip Frame, Cartridge Barrel, Trigger Lever, Plunger Rod, and Needle Hub
The Intraligamental Syringe uses a pistol-grip frame to convert controlled hand compression into measured anesthetic delivery through the cartridge system. The cartridge barrel receives the anesthetic cartridge and aligns it with the plunger rod so forward movement is transferred directly to the cartridge piston. The side viewing window allows the clinician to monitor cartridge seating and remaining anesthetic volume during repeated ligament-space injections. The trigger lever gives progressive mechanical control, which is clinically important because periodontal ligament injection is performed against dense fibrous tissue with higher resistance than buccal infiltration or palatal deposition. The rear plunger assembly provides loading, seating, and controlled piston engagement, while the needle hub directs a fine dental needle toward the gingival sulcus and root surface. The pistol-style body supports a stable hand position during posterior access and helps maintain needle angle beside molars, premolars, canines, and incisors. The mechanism has no ratchet because delivery depends on continuous tactile resistance, gradual lever pressure, and precise needle stabilization.
Periodontal Ligament Injection, Endodontic Rescue Anesthesia, Extraction, and Restorative Dentistry
During periodontal ligament anesthesia, the needle is positioned through the gingival sulcus with the bevel oriented toward the root surface, then advanced into the ligament space at the mesial or distal line angle of the selected tooth. The trigger is activated gradually so anesthetic is expressed in small controlled increments around the root. In endodontic treatment, the instrument supports supplemental anesthesia for irreversible pulpitis, mandibular molars, inflamed pulps, and incomplete inferior alveolar nerve block response before access opening, pulp chamber entry, canal negotiation, shaping, irrigation, and obturation. During restorative dentistry, it provides localized tooth anesthesia for crown preparation, deep caries excavation, composite restoration, matrix placement, inlay preparation, and bridge abutment work. In extraction workflow, the syringe supports additional periodontal anesthesia before luxator insertion, elevator use, root movement, and forceps delivery. Pediatric clinicians use the same tooth-specific method when broad lip, tongue, or cheek numbness is not desired after treatment. Periodontists use it before subgingival instrumentation, localized flap access, root planing, and gingival contouring around selected teeth.
0.5ml, 1ml, 2ml, 3ml, 5ml, 10ml, 20ml, 30ml, 50ml, and 60ml Selection
The 0.5ml variant is selected for minimal-volume tooth-specific anesthesia in pediatric care, anterior teeth, and localized periodontal ligament supplementation where a small anesthetic volume is required. The 1ml and 2ml options support routine PDL injection around single-rooted teeth, premolars, and endodontic rescue cases. The 3ml and 5ml variants suit multi-rooted teeth, extraction support, periodontal procedures, and restorative appointments requiring repeated delivery around one or more roots. The 10ml and 20ml options support higher-volume clinical setups, multi-chair use, teaching environments, and procedure sequencing where multiple localized injections are expected during the same session. The 30ml, 50ml, and 60ml sizes are ordered for broader departmental inventory planning, high-volume clinic workflows, institutional procurement, and repeated anesthesia preparation across dental operatories. The full size range allows procurement teams to align syringe configuration with clinical volume, procedure type, operator preference, chairside turnover, and department-level anesthesia instrument standardization.
German Stainless Steel, Polished Finish, Reprocessing, and Procurement Documentation
German Stainless Steel gives the Intraligamental Syringe the rigidity, corrosion resistance, and reusable durability required for repeated dental anesthesia workflows. A dental cartridge syringe must retain barrel alignment, cartridge chamber accuracy, plunger movement, trigger response, needle hub fit, side-window visibility, and smooth exterior surfaces because anesthetic delivery depends on mechanical stability and precise pressure transfer. The polished finish supports visual inspection after cleaning and helps reduce residue retention around the frame, chamber, hub, and trigger assembly. After use, the needle is removed, the anesthetic cartridge is discarded according to clinical protocol, the chamber is opened, the plunger path is cleaned, the trigger area is brushed, and the exterior body is wiped before sterilization workflow. CE marking, ISO-13485 certification, and FDA compliance support dental clinic purchasing, hospital procurement, distributor documentation, and international tender files. The listed price, reusable format, broad size range, MOQ of 1 piece, and return-and-replacement support help dental departments standardize intraligamental anesthesia inventory.